Back to Search Start Over

Perspectives of using (Ar-Xe) direct nuclear pumped laser at high temperatures

Authors :
Airat A. Mavlyutov
Aleksey I. Mis’kevich
Source :
AIP Conference Proceedings.
Publication Year :
1996
Publisher :
AIP, 1996.

Abstract

Possible physical reasons of overheating of Ar‐Xe direct nuclear pumped laser were investigated. The time‐dependent Ar‐Xe laser output was measured at temperatures 20, 150, 220 and 260 °C. It was shown that the true reason of temperature anomalies are the pollution of Ar‐Xe active media by water vapour which was desorbed from the walls of the laser cell at high temperature.

Details

ISSN :
0094243X
Database :
OpenAIRE
Journal :
AIP Conference Proceedings
Accession number :
edsair.doi...........ef5ac3ff9c173fcda65b53f586612f70
Full Text :
https://doi.org/10.1063/1.50559