An automatic system for controlling the quality of straws installed in the ATLAS TRT detector
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 524:142-145
- Publication Year :
- 2004
- Publisher :
- Elsevier BV, 2004.
-
Abstract
- This article describes an automatic system to control the quality of straws installed in the wheels of the end-cap Transition Radiation Tracker of the ATLAS experiment. The system tests both the straightness and the electrical insulation of the straws during installation. The testing time per straw is 9 s; consequently it takes about 2 h to measure one layer of straws. The off-line analysis takes 20 s per straw. With this system defects can be immediately detected and corrected. This clearly influences the future performance of the detector.
Details
- ISSN :
- 01689002
- Volume :
- 524
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :