Back to Search
Start Over
Fully-Integrated Planar Transformer With a Segmental Shunt for LLC Resonant Converters
- Source :
- IEEE Transactions on Industrial Electronics. 69:9145-9154
- Publication Year :
- 2022
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2022.
-
Abstract
- This paper presents two topologies which provide high leakage inductance in shunt-inserted integrated magnetic transformers. These differ from conventional designs by replacing the low-permeability magnetic shunt of a planar transformer with high-permeability magnetic shunt segments, separated by many small air gaps. This approach results in a shunt with the same bulk permeability as the conventional design, while using lower cost and readily available magnetic materials such as ferrite. A modelling and design approach which can estimate the leakage and magnetising inductances precisely is provided for each topology. Theoretical analysis is presented and verified using finite-element analysis and experimental implementation. AC resistance analysis for both transformer topologies is also presented. In addition, an LLC resonant converter is built to verify the performance of the proposed fully-integrated magnetic transformers in practice. It is shown that the proposed topologies can integrate all three magnetic components of an isolated LLC resonant converter in a single planar transformer, which reduces the converters volume and cost.
- Subjects :
- Leakage inductance
Materials science
Topology (electrical circuits)
Converters
equipment and supplies
law.invention
Planar
Control and Systems Engineering
law
Electronic engineering
Ferrite (magnet)
Electrical and Electronic Engineering
Transformer
human activities
Shunt (electrical)
Leakage (electronics)
Subjects
Details
- ISSN :
- 15579948 and 02780046
- Volume :
- 69
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Industrial Electronics
- Accession number :
- edsair.doi...........e9c4a7792dd09997cf87e41eaefcb474