Back to Search Start Over

Level 3 system at CDF

Authors :
J.T. Carroll
Andrew Beretvas
Y. Morita
M. Larwill
U. Joshi
T. Devlin
S. Miyashita
B. Flaugher
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 263:199-205
Publication Year :
1988
Publisher :
Elsevier BV, 1988.

Abstract

Level 3 uses 32-bit microprocessors installed in VME crates to execute FORTRAN filter algorithms. The system is integrated into the CDF FASTBUS data acquisition network which is designed to support event rates of 100 Hz into level 3. Filter algorithms access event data in the same detector bank format as used for off-line analysis.

Details

ISSN :
01689002
Volume :
263
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi...........e3e1a803655bc8da03fa6b7aa911530e
Full Text :
https://doi.org/10.1016/0168-9002(88)91035-2