Back to Search Start Over

Functional outcome of orthogonal plating in treatment of distal humerus fracture

Authors :
Rajeev Kelkar
Deepak Singh Rajput
Source :
International Journal of Orthopaedics Sciences. 4:278-283
Publication Year :
2018
Publisher :
AkiNik Publications, 2018.

Abstract

Background: The study was conducted to evaluate the outcome of orthogonal plating system in distal humerus intraarticular fracture. Material and Methods: 15 patients of age between 18 to 60 yrs with fracture distal end of humerus with intraarticular extension were evaluated, with the mean age group of 37 to find the functional outcome of Orthogonal plating using olecranon osteotomy approach. Results: The mean union time was 9.53 weeks. The arc of flexion was 99.66o. Average mayo elbow performance score (MEPS) was 83. There were 2 case of infection. One case of implant failure noted secondary to infection leading to implant removal. Discussion and Conclusion: The following results were assessed: operating time, arc of flexion and extension, time to fracture union, functional recovery, and complications. By using proper principles of stable fracture fixation and appropriate exposure in intraarticular fracture (with transolecrenon approach) a good reduction can be achieved which leads to good union, which helps in early mobilization and restoring elbow functions with early intensive physiotherapy.

Details

ISSN :
23951958
Volume :
4
Database :
OpenAIRE
Journal :
International Journal of Orthopaedics Sciences
Accession number :
edsair.doi...........e1aa0139d94cb881441433d93f67a884
Full Text :
https://doi.org/10.22271/ortho.2018.v4.i2e.41