Abstract

In this paper, based on the F8 stick-slip fault section of Longxi Tunnel in China, the effect of the anti-breaking measure of rigid-flexible composite (reinforcement of the secondary lining & construction of the reducing dislocation layer between the primary support and the secondary lining) is studied by using the method of indoor model test in order to improve the anti-breaking performance of the tunnel across stick-slip fault in the actual tunnel engineering. The test results show that the anti-breaking effect is limited by adopting structural strengthening measures to resist the influence of stick-slip dislocation on the tunnel structure and the anti-breaking effect is obvious by adopting the measures of reducing dislocation layer only. However, the structural safety of the tunnel with stick-slip fault in the strong seismic intensity area can be greatly improved by adopting the anti-breaking measure of rigid-flexible composite, and the structural safety factor can be significantly improved. The research results of this paper can provide a reference for the anti-breaking design of the tunnel across stick-slip fault in the high seismic intensity area.

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........e0f596b46133a22d6f1eb507d2ce80fa
Full Text :
https://doi.org/10.21203/rs.3.rs-370644/v1