Back to Search
Start Over
Tests on timber frame walls under in-plane forces: part 2
- Source :
- Proceedings of the Institution of Civil Engineers - Structures and Buildings. 168:840-852
- Publication Year :
- 2015
- Publisher :
- Thomas Telford Ltd., 2015.
-
Abstract
- The mechanical behaviour of timber frame shear walls subjected to in-plane forces has been investigated through full-scale tests. Eleven monotonic and 11 cyclic tests were performed on full-scale shear walls, each 2·5 m high and 2·5 m long. Different variables were changed during the tests as follows. Different vertical loads were applied, different angle brackets and hold-downs were used and different sheathing panels were connected to the timber frame. Also, the influence of openings was investigated. Furthermore, two walls with non-structural finishing were tested in order to correlate the inter-storey drift with the level of damage. This paper (part 2) reports on a comparison between different test results, permitting evaluation of the influence of each variable on the stiffness and the resistance of the walls. Moreover, the theoretical formulae presented in a companion paper (part 1) were compared with the outcome of the tests, and good agreement was found. The racking resistance predicted by Eurocode 5 was also checked using the data obtained from the tests.
Details
- ISSN :
- 17517702 and 09650911
- Volume :
- 168
- Database :
- OpenAIRE
- Journal :
- Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Accession number :
- edsair.doi...........e04fd97b4521d6e44565325cf0543e43
- Full Text :
- https://doi.org/10.1680/stbu.13.00108