Assessment of heart rate agreement on continuous photoplethysmography monitoring using a smartwatch versus beat-to-beat synchronized ECG monitoring

Authors :
S Evens
Laurent Pison
Jeroen Dauw
Hein Heidbuchel
Christophe J.P. Smeets
Henri Gruwez
F Wouters
Pieter M. Vandervoort
Peter Haemers
Lieselotte Knaepen
Lien Desteghe
S Deferm
Pauline Dreesen
Source :
European Heart Journal. 42
Publication Year :
2021
Publisher :
Oxford University Press (OUP), 2021.

Abstract

Background In the awakening era of mobile health, wearables equipped with photoplethysmography (PPG) technology to monitor the heart rate (HR) and rhythm are on the rise. Smartwatches and wristbands enable HR monitoring for consumers at massive scale. Unfortunately, once consumers become patients, physicians are limited by insufficient evidence to support the clinical use of PPG based wearables. Accurate identification of heartbeats is the first step in the interpretation of PPG traces and should be validated. Purpose To assess the agreement between continuous PPG monitoring using a smartwatch and continuous ECG Holter monitoring in the identification of heartbeats and calculation of the HR. Methods One hundred patients (≥18 years) without a pacemaker-dependent heart rhythm who were referred to a university hospital and a large tertiary hospital for elective 24-hour ECG Holter monitoring were asked to wear a continuous PPG monitoring smartwatch (i.e. Samsung GWA2 or Empatica E4) simultaneously with the 24-hour Holter monitor. All activities of daily life were allowed. The ECG trace and PPG waveform were synchronised and fragmented in one-minute fragments. The one-minute ECG fragments were labelled as AF, non-AF, or insufficient quality based on the routine clinical interpretation (i.e. software + physician overreading), and the average HR during each fragment was calculated by Holter algorithm. The PPG fragments were analysed by an artificial intelligence (AI) algorithm (i.e. FibriCheck) that labelled fragments as sufficient or insufficient quality, identified the number of heartbeats and calculated the HR. The agreement between the HR on ECG and PPG in sufficient quality tracings was analysed with linear regression, Pearson's product-moment correlation and Bland-Altman analysis. A subanalysis was performed for AF rhythm and non-AF rhythms. Results A total of 72,725 simultaneous ECG and PPG one-minute fragments were recorded in 96 patients, after excluding 4 patients (due to 3 Holter and 1 smartwatch technical error) and 42,520 minutes (36.9%) of insufficient quality (ECG 1,454 (1.3%); PPG 25,704 (22.3%), ECG and PPG 15,362 (13.3%)). The correlation (r=0.935) between ECG and PPG HR was statistically significant (CI 0.934–0.936; P Conclusion The AI algorithm analysing continuous out-of-hospital PPG tracings can annotate heartbeats and assess HR without a clinically significant bias compared to continuous ECG monitoring, both during AF and non-AF rhythms in a heterogenous patient population. Funding Acknowledgement Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Research Foundation-Flanders, Strategic Basic Research Fund Correlation plot & Bland-Altman plot

Details

ISSN :
15229645 and 0195668X
Volume :
42
Database :
OpenAIRE
Journal :
European Heart Journal
Accession number :
edsair.doi...........e00f5c9230f5d32ebfd68d32644e14cb