Back to Search
Start Over
Anatomical ACL Reconstruction can Restore the Natural Knee Kinematics than Isometric ACL Reconstruction During the Stance Phase of Walking
- Source :
- International Journal of Precision Engineering and Manufacturing. 21:1127-1134
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- The attachment locations of anterior cruciate ligament (ACL) grafts during reconstruction have been reported to influence knee joint function. However, there are controversial opinions on femoral ACL attachment locations for restoring normal knee kinematics. The knee stability and ACL force by different ACL attachment locations could be predicted using the musculoskeletal model simulation. The objectives of this study are to develop a detailed musculoskeletal knee model and to quantify the effect of ACL graft attachment locations on knee kinematics and graft force. Five normal subjects walked at a self-selected speed, and motion data were captured. A detailed knee model including 14 ligaments was developed for dynamics simulation using cadaveric specimen data, which were previously published and are open to public access. The ACL bundles of the model were removed and replaced with ACL grafts to develop anatomical and isometric ACL-reconstructed knee models; the femoral anatomical footprint and isometric locations were used, respectively. After the knee models were embedded in a full-body template model from the AnyBody Managed Model Repository, the full-body musculoskeletal model was simulated using the measured gait data. The isometric reconstruction model had significantly large anterior translation and internal rotation than the intact and anatomical reconstruction model. The average differences between the isometric reconstruction and intact models were 4.5 mm and 3.0° for tibial anterior translation and internal rotation, respectively. The ACL tensional force in the isometric reconstruction model was significantly lower than that in the intact model. Anatomical reconstruction could closely restore the normal knee kinematics.
- Subjects :
- Orthodontics
0209 industrial biotechnology
business.industry
Stance phase
Mechanical Engineering
Anterior cruciate ligament
Knee kinematics
02 engineering and technology
Isometric exercise
Knee Joint
musculoskeletal system
Gait
Industrial and Manufacturing Engineering
Public access
surgical procedures, operative
020303 mechanical engineering & transports
020901 industrial engineering & automation
medicine.anatomical_structure
0203 mechanical engineering
medicine
Electrical and Electronic Engineering
Cadaveric spasm
business
human activities
Subjects
Details
- ISSN :
- 20054602 and 22347593
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- International Journal of Precision Engineering and Manufacturing
- Accession number :
- edsair.doi...........de621041077ccd37ba440ca042ded47c