Scintillation response of nuclear particle detectors

Authors :
Karo Michaelian
A. Menchaca-Rocha
E. Belmont-Moreno
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 356:297-303
Publication Year :
1995
Publisher :
Elsevier BV, 1995.

Abstract

We derive simple algebraic expressions for the ion-induced light output response of most of the popular scintillation detectors used in nuclear and particle physics. The analytical calculation is based on a model for the energy deposition by secondary electrons scattered along the track of the ion, and the subsequent energy transport to luminescence centers. Predictions are compared with published experimental data for various scintillating materials over a wide range of incident ions and energies.

Details

ISSN :
01689002
Volume :
356
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi...........ddc3bc9fa7c3ab78b789fc7a480ef653
Full Text :
https://doi.org/10.1016/0168-9002(94)01252-0