Back to Search Start Over

A study of the CO2 capture pilot plant by amine absorption

Authors :
Ji Hyun Lee
Kyung Ryoung Jang
No-Sang Kwak
Jae-Goo Shim
In Young Lee
Source :
Energy. 47:41-46
Publication Year :
2012
Publisher :
Elsevier BV, 2012.

Abstract

A pilot plant for CO 2 recovery of 2 ton-CO 2 /day from flue gas emitted from a 500 MW coal fired power plant was tested with aqueous amine absorbents. Based on a chemical absorption/regeneration process with 30 wt% aqueous monoethanolamine (MEA) solution, we studied the CO 2 recovery as a function of flow rate and input location of absorbent, pressure and temperature of stripper, and temperature of flue gas. Experimental data include the temperature profile of the absorber/stripper and CO 2 lean/rich loading values, which remained stable during the operation. We evaluated the energy requirement for regeneration of aqueous amine and the degree of CO 2 removal. While regeneration energy of aqueous amine increased with an increase in flue gas temperature and stripper pressure, it decreased with an increase in injection height of absorbent. The optimum point in flow rate of absorbent was 1300 kg/h in 350 Sm 3 /h flue gas. The regeneration energy using 30 wt% MEA solution was 3.92 GJ/ton CO 2 in 90% CO 2 removal, flue gas temperature of 40 °C, stripper pressure of 0.5 kgf/cm 2 and L/G ratio of 3.7 kg/Sm 3 . In addition, corrosion rate of the pilot plant were measured in six points. It is the largest as 79.11 mpy in the bottom of the stripper tower.

Details

ISSN :
03605442
Volume :
47
Database :
OpenAIRE
Journal :
Energy
Accession number :
edsair.doi...........dc92166abf68cafd03ca62d39e80a8f1
Full Text :
https://doi.org/10.1016/j.energy.2012.07.016