Back to Search
Start Over
Circuits with surface modifying additive alter the haemodynamic response to cardiopulmonary bypass1
- Source :
- European Journal of Cardio-Thoracic Surgery. 15:353-358
- Publication Year :
- 1999
- Publisher :
- Oxford University Press (OUP), 1999.
-
Abstract
- Objective: Blood contact with synthetic surfaces during cardiopulmonary bypass (CPB), inevitably results in the activation of a variety of interrelated pathways of inflammation and coagulation that may contribute to postoperative complications in cardiac surgery patients. The objective of this trial was to evaluate clinical events and complement activation related to the use of a novel biomaterial, into which a surface modifying additive had been incorporated into the polymer used to prepare the bypass circuit. Methods: A prospective, doubleblind trial was carried out with 34 patients randomized to surgery, with either a standard circuit or a circuit treated (‘tip to tip’) with the surface modifying additive. Variables recorded included perioperative haemodynamics, volume replacement, a-agonist and inotrope use. Terminal complement complex (SC5b-9) was measured using an ELISA. Results: Upon initiation of bypass, there was a decrease in mean arterial pressure (MAP) in the control group, not seen in the test group ( P = 0.0005, ANOVA). There was a decrease in the total volume of replacement fluid given intraoperatively in the test group as compared with the control group (total plus prime; control 5.3 ∠ 1.2 L, test 4.4 ∠ 1.9 L, P = 0.03, Mann‐Whitney test). There was a trend to decreased need for inotrope infusion in the test group after CPB (test 1/17, control 6/17, Fisher exact test; P = 0.085). No difference was seen in the generation of terminal complement complex between the groups either during or after CPB. Conclusions: The decrease in blood pressure in the control group, upon the initiation of CPB, did not occur in patients undergoing CPB with the circuit prepared with the surface modifying additive. The decrease in blood pressure was likely associated with the increase in total administered fluids intraoperatively (approximately 1 l/patient) and perhaps the trend towards higher use of inotropes in the control patients as opposed to the test patients. These haemodynamic changes did not appear to be related to complement activation early in CPB. © 1999 Elsevier Science B.V. All rights reserved.
- Subjects :
- Pulmonary and Respiratory Medicine
Inotrope
Mean arterial pressure
medicine.medical_specialty
Haemodynamic response
business.industry
Hemodynamics
General Medicine
law.invention
Cardiac surgery
symbols.namesake
Blood pressure
law
Anesthesia
symbols
Cardiopulmonary bypass
medicine
Surgery
Cardiology and Cardiovascular Medicine
business
Fisher's exact test
Subjects
Details
- ISSN :
- 1873734X and 10107940
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- European Journal of Cardio-Thoracic Surgery
- Accession number :
- edsair.doi...........daaced7d75176646434bce287c974e51
- Full Text :
- https://doi.org/10.1016/s1010-7940(99)00015-9