Back to Search
Start Over
GAMMASPHERE-timing and signal processing aspects of the BGO Compton shield
- Source :
- IEEE Transactions on Nuclear Science. 41:1135-1139
- Publication Year :
- 1994
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 1994.
-
Abstract
- We describe the design of the signal processing system and considerations involved in the timing performance of the BGO scintillator Compton shield that surrounds each of the 110 large germanium detectors used in a geodesic array covering the complete sphere surrounding the target in GAMMASPHERE. It is shown that the main timing limitation results from the statistics of photoelectron emission from the photocathode of the photomultiplier tubes (PMTs) that observe the light from the scintillators and that achieving the required timing demands triggering on the first photoelectron. The circuits to do this for a single detector assembly must be able to deal with signals from 14 PMTs associated with the 7 elements of the scintillator shield surrounding each germanium detector. >
- Subjects :
- Physics
Nuclear and High Energy Physics
Photomultiplier
Physics::Instrumentation and Detectors
business.industry
Detector
Scintillator
Particle detector
Photocathode
Semiconductor detector
Nuclear physics
Optics
Nuclear Energy and Engineering
Scintillation counter
Gammasphere
Electrical and Electronic Engineering
Nuclear Experiment
business
Subjects
Details
- ISSN :
- 15581578 and 00189499
- Volume :
- 41
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Nuclear Science
- Accession number :
- edsair.doi...........da41faaba1383c9e8bcf445477cc79be
- Full Text :
- https://doi.org/10.1109/23.322871