Back to Search Start Over

3-D Shielding Analyses of the Vertical and Mid-Plane Ports in ITER

Authors :
R.T. Santoro
Hiromasa Iida
L. Petrizzi
Mohamed E. Sawan
D. Valenza
Source :
Fusion Technology. 30:606-610
Publication Year :
1996
Publisher :
American Nuclear Society, 1996.

Abstract

A three dimensional (3-D) shielding analysis of the International Thermonuclear Experimental Reactor (ITER) has been performed with the aim of calculating the nuclear heating on the magnet system, correlating it to the existing vertical and horizontal ports. When these openings are left unshielded, more than 50 kW are calculated for the upper half of Toroidal Field Coil system and two of the Poloidal Field Coils. A simple plug, with same thickness as of the vacuum vessel can lower the heating to meet the imposed requirements. 5 refs., 6 figs., 4 tabs.

Details

ISSN :
07481896
Volume :
30
Database :
OpenAIRE
Journal :
Fusion Technology
Accession number :
edsair.doi...........d8e72383956ff9d22b471ec6188db2c4
Full Text :
https://doi.org/10.13182/fst96-a11963005