Back to Search Start Over

Switching Signals Generation Technique for Minimizing the RMS Tracking Error in Active Filters

Authors :
Maria Isabel Milanes Montero
E. Romero
Fermin Barrero Gonzalez
José Miguel Montero Milanés
Source :
Renewable Energy and Power Quality Journal. 1:581-584
Publication Year :
2003
Publisher :
AEDERMACP (European Association for the Development of Renewable Energies and Power Quality), 2003.

Abstract

In this paper a variation of the Pulse Width Modulation (PWM) operation technique, which we have called "of adjustable ramps", is analysed. This technique will be applied to an active filter in order to compensate the low harmonics content present in a load current. The aim is to prove that the proposed technique, whose objective is minimising the Root Mean Square (RMS) tracking error between the reference and the real currents, achieves a better performance than the usual PWM techniques in active filtering. Simulation results comparing several gen eration techniques will be presented. These techniques will be analysed in terms of the total and individual harmonic distortion (THD and IHDi) in the supply current.

Details

ISSN :
2172038X
Volume :
1
Database :
OpenAIRE
Journal :
Renewable Energy and Power Quality Journal
Accession number :
edsair.doi...........d742db1347e86a8dec73053af7eb4124
Full Text :
https://doi.org/10.24084/repqj01.431