A Modified Dickson Charge Pump Circuit with High Efficiency and High Output Voltage
- Source :
- IEICE Transactions on Electronics. :228-231
- Publication Year :
- 2008
- Publisher :
- Institute of Electronics, Information and Communications Engineers (IEICE), 2008.
-
Abstract
- A power-efficient Dickson-based charge pump circuit is proposed and verified in this paper. Using a PMOS transfer switch in the new circuit solves the problem of the output voltage loss and its body control switch can suppress the parasitic bipolar action. Comparing this new one with the conventional circuit, the new circuit generates output voltage as high as 2.9VDD while the conventional one only 2VDD. For their efficiency values, the new circuit has better efficiency than the conventional one by as much as 14.5% with the area overhead of 12.2% using 3.5-μm and 40-V CMOS high-voltage process.
- Subjects :
- Engineering
business.industry
Electrical engineering
High voltage
Hardware_PERFORMANCEANDRELIABILITY
Transfer switch
Discrete circuit
Electronic, Optical and Magnetic Materials
RL circuit
Zero cross circuit
Hardware_INTEGRATEDCIRCUITS
Electronic engineering
Charge pump
Equivalent circuit
Electrical and Electronic Engineering
business
Short circuit
Hardware_LOGICDESIGN
Subjects
Details
- ISSN :
- 17451353 and 09168524
- Database :
- OpenAIRE
- Journal :
- IEICE Transactions on Electronics
- Accession number :
- edsair.doi...........d43f7f554bf6ae353eb10a474bcc7d0a
- Full Text :
- https://doi.org/10.1093/ietele/e91-c.2.228