Optimum spacing between grooved tubes: An experimental study

Authors :
Asif Afzal
A. D. Mohammed Samee
R. K. Abdul Razak
Hurmathulla Khan
Sher Afghan Khan
Source :
Journal of Mechanical Science and Technology. 34:469-475
Publication Year :
2020
Publisher :
Springer Science and Business Media LLC, 2020.

Abstract

An experimental study on optimum spacing between grooved tubes is reported in this paper. Two grooved tubes having pitch of 10 mm and 15 mm and a plain tube were considered for the heat transfer analysis. The spacing between two tubes with same pitch was varied from 10 mm to 35 mm with a step size of 5 mm. Velocity of air flowing over the tube surfaces was changed from 0.4 m/s to 1 m/s using a blower fan. Based on Nusselt number (Nu) the optimum spacing between the tubes was decided. The optimum spacing between grooved tubes of pitch 10 mm and 15 mm was compared with that of plain tubes. From the experimental analysis it was noticed that with increase in air velocity (increase in Reynolds number) the tube surface temperature reduced irrespective of any tube considered. Nu increased with increase in air velocity for all the tubes. The important conclusion drawn from the present study was that, there exists a limiting spacing (optimum) between the tubes above which no change in Nu was observed. Spacing of 30 mm was found to be the optimum spacing between the tubes irrespective of its surface geometry modifications.

Details

ISSN :
19763824 and 1738494X
Volume :
34
Database :
OpenAIRE
Journal :
Journal of Mechanical Science and Technology
Accession number :
edsair.doi...........d3a67a088d71a84924682604d51b22e0
Full Text :
https://doi.org/10.1007/s12206-019-1244-7