Lifetime performance evaluation of stick and panel curtain wall systems by full-scale testing
- Source :
- Construction and Building Materials. 170:254-271
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- This study presents stick and panel curtain wall systems’ lifetime performance comparison by conducting full-scale testing according to a proposed test method. The procedure is based on Turkish standards and supported by CWCT. Besides weather tightness, wind and seismic resistance tests, thermal cycling are included to the procedure in two-stages between −10 °C and +50 °C considering temperatures in 20 years in Istanbul. Results showed that stick system might be more fragile than panel system under the same conditions. This study is thought to be a leading work in lifetime performance assessment of such curtain wall types by considering specific local conditions.
- Subjects :
- Computer science
business.industry
020209 energy
Work (physics)
0211 other engineering and technologies
02 engineering and technology
Building and Construction
Temperature cycling
Test method
Structural engineering
Performance comparison
021105 building & construction
0202 electrical engineering, electronic engineering, information engineering
General Materials Science
Curtain wall
Seismic resistance
business
Civil and Structural Engineering
Full scale testing
Subjects
Details
- ISSN :
- 09500618
- Volume :
- 170
- Database :
- OpenAIRE
- Journal :
- Construction and Building Materials
- Accession number :
- edsair.doi...........cf117ee407d9b3d915fb8ea9ffd4e903
- Full Text :
- https://doi.org/10.1016/j.conbuildmat.2018.03.061