Back to Search Start Over

Comparison of centric and reverse-centric trajectories for highly accelerated three-dimensional saturation recovery cardiac perfusion imaging

Authors :
Eugene G. Kholmovski
Ganesh Adluru
Jian Xu
Haonan Wang
Neal K. Bangerter
Edward V. R. DiBella
Daniel J. Park
Source :
Magnetic Resonance in Medicine. 74:1070-1076
Publication Year :
2014
Publisher :
Wiley, 2014.

Abstract

Purpose Highly undersampled three-dimensional (3D) saturation-recovery sequences are affected by k-space trajectory since the magnetization does not reach steady state during the acquisition and the slab excitation profile yields different flip angles in different slices. This study compares centric and reverse-centric 3D cardiac perfusion imaging. Methods An undersampled (98 phase encodes) 3D ECG-gated saturation-recovery sequence that alternates centric and reverse-centric acquisitions each time frame was used to image phantoms and in vivo subjects. Flip angle variation across the slices was measured, and contrast with each trajectory was analyzed via Bloch simulation. Results Significant variations in flip angle were observed across slices, leading to larger signal variation across slices for the centric acquisition. In simulation, severe transient artifacts were observed when using the centric trajectory with higher flip angles, placing practical limits on the maximum flip angle used. The reverse-centric trajectory provided less contrast, but was more robust to flip angle variations. Conclusion Both of the k-space trajectories can provide reasonable image quality. The centric trajectory can have higher CNR, but is more sensitive to flip angle variation. The reverse-centric trajectory is more robust to flip angle variation. Magn Reson Med 74:1070–1076, 2015. © 2014 Wiley Periodicals, Inc.

Details

ISSN :
07403194
Volume :
74
Database :
OpenAIRE
Journal :
Magnetic Resonance in Medicine
Accession number :
edsair.doi...........cdccc2bdd83b112712ab94103cfc0256
Full Text :
https://doi.org/10.1002/mrm.25478