Reliability and Validity of the iLOAD Application for Monitoring the Mean Set Velocity During the Back Squat and Bench Press Exercises Performed Against Different Loads
- Source :
- Journal of Strength and Conditioning Research. 35:S57-S65
- Publication Year :
- 2020
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2020.
-
Abstract
- Perez-Castilla, A, Boullosa, D, and Garcia-Ramos, A. Reliability and validity of the iLOAD application for monitoring the mean set velocity during the back squat and bench press exercises performed against different loads. J Strength Cond Res 35(2S): S57-S65, 2021-This study aimed to evaluate the reliability and validity of a smartphone application (iLOAD) for the monitoring of mean concentric velocity (MV) during resistance training sets. Twenty males completed 2 identical sessions consisting of one set of 10 repetitions against 4 loads (25, 40, 55, 70% of the one repetition maximum [1RM]) during the back squat and bench press exercises. The MV of the 5 initial repetitions and for the whole set were determined simultaneously with the iLOAD application and a linear velocity transducer (LVT). Two independent researchers operated the iLOAD application during the experimental sessions to evaluate the interrater agreement for the assessment of MV. An acceptable but generally lower reliability was observed for iLOAD (coefficient of variation [CV] range: 5.61-9.79%) compared to the LVT (CV range: 4.51-8.18%) at 25-40-55% of 1RM, whereas the reliability at 75% of 1RM was acceptable for the LVT during the bench press (CV range: 6.37-8.26%), but it was unacceptable for the iLOAD during both exercises (CV range: 11.3-12.8%) and for the LVT during the back squat (CV range: 11.3-17.4%). Small to moderate differences (ES range: 0.24-1.04) and very high to practically perfect correlations (r range: 0.70-0.90) were observed between the iLOAD and the LVT. A very high agreement was observed between both raters for the recording of MV during the back squat and bench press exercises (r ≥ 0.98). Taken together, these results suggest that the iLOAD application can be confidently used to quantify the MV of training sets during the squat and bench press exercises not performed to failure.
- Subjects :
- Coefficient of variation
Physical Therapy, Sports Therapy and Rehabilitation
Squat
030229 sport sciences
General Medicine
030204 cardiovascular system & hematology
Concentric
Bench press
Set (abstract data type)
03 medical and health sciences
0302 clinical medicine
One-repetition maximum
Range (statistics)
Orthopedics and Sports Medicine
Simulation
Reliability (statistics)
Mathematics
Subjects
Details
- ISSN :
- 10648011
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Journal of Strength and Conditioning Research
- Accession number :
- edsair.doi...........cdb6d907a14f6fce1459c1095e24baa2
- Full Text :
- https://doi.org/10.1519/jsc.0000000000003739