Library-based scatter correction for dedicated cone beam breast CT: a feasibility study
- Source :
- SPIE Proceedings.
- Publication Year :
- 2016
- Publisher :
- SPIE, 2016.
-
Abstract
- Purpose: Scatter errors are detrimental to cone-beam breast CT (CBBCT) accuracy and obscure the visibility of calcifications and soft-tissue lesions. In this work, we propose practical yet effective scatter correction for CBBCT using a library-based method and investigate its feasibility via small-group patient studies. Method: Based on a simplified breast model with varying breast sizes, we generate a scatter library using Monte-Carlo (MC) simulation. Breasts are approximated as semi-ellipsoids with homogeneous glandular/adipose tissue mixture. On each patient CBBCT projection dataset, an initial estimate of scatter distribution is selected from the pre-computed scatter library by measuring the corresponding breast size on raw projections and the glandular fraction on a first-pass CBBCT reconstruction. Then the selected scatter distribution is modified by estimating the spatial translation of the breast between MC simulation and the clinical scan. Scatter correction is finally performed by subtracting the estimated scatter from raw projections. Results: On two sets of clinical patient CBBCT data with different breast sizes, the proposed method effectively reduces cupping artifact and improves the image contrast by an average factor of 2, with an efficient processing time of 200ms per conebeam projection. Conclusion: Compared with existing scatter correction approaches on CBBCT, the proposed library-based method is clinically advantageous in that it requires no additional scans or hardware modifications. As the MC simulations are pre-computed, our method achieves a high computational efficiency on each patient dataset. The library-based method has shown great promise as a practical tool for effective scatter correction on clinical CBBCT.
- Subjects :
- medicine.medical_specialty
Artifact (error)
Computer science
business.industry
Monte Carlo method
Translation (geometry)
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Homogeneous
030220 oncology & carcinogenesis
medicine
Medical physics
Computer vision
Artificial intelligence
Projection (set theory)
business
Beam (structure)
Scatter correction
Breast ct
Subjects
Details
- ISSN :
- 0277786X
- Database :
- OpenAIRE
- Journal :
- SPIE Proceedings
- Accession number :
- edsair.doi...........cc046e60659becb406e5aa064565b95d