Efficient HPLC method for determination of cephalosporin residues on spiked stainless-steel plates and human plasma: application of a worst-case product for Cosa®CIP
- Source :
- International Journal of Environmental Analytical Chemistry. 100:82-98
- Publication Year :
- 2019
- Publisher :
- Informa UK Limited, 2019.
-
Abstract
- The main objective of the cleaning validation procedure is to verify the effectiveness of the cleaning procedure for removal and minimising the risk of cross-contamination, a topic that has become ...
- Subjects :
- Chromatography
Materials science
medicine.drug_class
Health, Toxicology and Mutagenesis
010401 analytical chemistry
Cephalosporin
Public Health, Environmental and Occupational Health
Soil Science
010501 environmental sciences
Cleaning validation
01 natural sciences
Pollution
0104 chemical sciences
Analytical Chemistry
Human plasma
Product (mathematics)
medicine
Environmental Chemistry
Steel plates
Hplc method
Waste Management and Disposal
0105 earth and related environmental sciences
Water Science and Technology
Subjects
Details
- ISSN :
- 10290397 and 03067319
- Volume :
- 100
- Database :
- OpenAIRE
- Journal :
- International Journal of Environmental Analytical Chemistry
- Accession number :
- edsair.doi...........c7bfebb96e844047f99e9d9ebb197e50
- Full Text :
- https://doi.org/10.1080/03067319.2019.1631301