Back to Search Start Over

Unstable charging of Al/sub 2/O/sub 3/ spacers at high electrical stress

Authors :
A.J.M. Pemen
H.W.M. Smulders
P.A.A.F. Wouters
Source :
Proceedings ISDEIV. 18th International Symposium on Discharges and Electrical Insulation in Vacuum (Cat. No.98CH36073).
Publication Year :
2002
Publisher :
IEEE, 2002.

Abstract

Partial discharge activity is measured at AC voltages close to breakdown of a 5 mm thick spacer. Patterns as a function of the phase angle of the applied voltage are observed which can be ascribed to charging processes on the insulator. Besides a stable regime of discharges, sudden changes in behaviour may also occur. These patterns often emerge as bursts (few seconds or minutes) after which they either quench or lead to a full breakdown.

Details

Database :
OpenAIRE
Journal :
Proceedings ISDEIV. 18th International Symposium on Discharges and Electrical Insulation in Vacuum (Cat. No.98CH36073)
Accession number :
edsair.doi...........c57a845eca4ab7712e1ff6a81970a985
Full Text :
https://doi.org/10.1109/deiv.1998.740601