Back to Search Start Over

Abstract P2031: Evaluation Of Adenosine Monophosphate-activated Protein Kinase Activator MK-8722 In Human Induced Pluripotent Stem Cell Derived Cardiomyocyte Monolayer And Microtissue (Biowire II) Models

Authors :
John P Imredy
Holly Clouse
Armando Lagrutta
Michael P Graziano
Krista M Durney
Wilson Hsieh
Jamie Gearhart
Brian Schriver
Nathan W Bay
Nicole T Feric
Source :
Circulation Research. 131
Publication Year :
2022
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2022.

Abstract

MK-8722, a systemic pan-AMPK activator improves glucose homeostasis in animal models of diabetes, but causes cardiac hypertrophy # . Two- and 3-dimensional tissue (2D,3D) constructs of human induced pluripotent stem cell derived cardiomyocytes (CM) (iCells, Fujifilm/CDI) were used to probe the translatability of cardiac hypertrophy and the role of AMPK in cardiomyocyte function. Chronic 10-day exposure (2 μM and 10 μM MK-8722) of iCell cardiomyocyte 2D monolayers, probed via monitoring of cellular impedance (CardioECR, Agilent), revealed a decrease in beat amplitude (-13%,2μM;-49%,10μM) as well as an increase in excitability, based on the ability to follow higher pacing frequencies (+81%,2uM;+34%,10uM). Direct force measurements in 3D iCell CM tissues (Biowire II, TARA Biosystems) reported loss of contractility when stimulated at 1Hz (-74%,2μM;-90%,10 μM), as well as changes in passive resting tension (+18%,2μM;-75%,10 μM) over chronic six-week exposure. MK-8722 caused a marked increase in Biowire excitability as revealed by a large drop in the voltage threshold of entrainment of paced tissues (-36%,2μM;-43%,10 μM). The increased excitability of both 2D and 3D CM models suggests a cellular correlate of the increased electrocardiographic QRS amplitude observed in rhesus monkeys upon chronic dosing with MK-8722 # . Hypertrophy of the Biowires could be clearly observed at the end of the 6-week incubation and presented as increased microtissue widths (+5%,2μM; +10%,10μM) and thickened regions of attachment to the chamber force sensors at each end of the Biowire. Volume estimation revealed increases (+22.3%, 2μM; +31.4%, 10 μM) in Biowire tissue volumes that were comparable to heart hypertrophic changes in preclinical test species # (mouse, rat, and rhesus monkey). The effect of 10μM MK-8722 was more pronounced when treatment began before tissues had completed a multi-week electrical stimulation maturation protocol, rather than after. The functional effects in both 2D and 3D CM models, and the contractile and structural readouts of the 3D Biowire model were highly informative in the interpretation of the clinical applicability of the pleiotropic cardiac effects of MK-8722 observed in preclinical testing. # Myers, et al. Science 357, p 507-511 (2017)

Details

ISSN :
15244571 and 00097330
Volume :
131
Database :
OpenAIRE
Journal :
Circulation Research
Accession number :
edsair.doi...........c49089682703f9d66163317efcdbb52c