Back to Search
Start Over
Structural Analysis of the ITER Thermal Shield for Final Design Verification
- Source :
- IEEE Transactions on Plasma Science. 42:1770-1774
- Publication Year :
- 2014
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2014.
-
Abstract
- The structural integrity of the ITER thermal shield (TS) has been verified by structural analysis. In this paper, the analysis process methodology and demonstration of the structural integrity for the TS are described. The analysis is performed for the TS global models and detailed models, such as supports and joints. TS joints in the shell model are modeled using orthotropic material properties. To verify the structural reliability for the TS, plastic collapse, buckling, ratcheting, and fatigue are assessed in accordance with ASME Section VIII, Div. 2.
Details
- ISSN :
- 19399375 and 00933813
- Volume :
- 42
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Plasma Science
- Accession number :
- edsair.doi...........c23e638bc390b024da5340552de4f9fd
- Full Text :
- https://doi.org/10.1109/tps.2014.2321173