Back to Search
Start Over
Clinic time required to manage cardiac implantable electronic device patients: a time and motion workflow evaluation
- Source :
- European Heart Journal. 41
- Publication Year :
- 2020
- Publisher :
- Oxford University Press (OUP), 2020.
-
Abstract
- Background The population with cardiac implantable electronic devices (CIEDs) is growing, creating workload for device clinics to manage these patients. However, the CIED follow-up workflow is poorly understood. This study sought to characterize the workflow and staff time for CIED patient management. Methods A time and motion workflow evaluation was performed in 6 U.S. CIED clinics, which manage an average of 4,217 patients. Each task involved in CIED management was repeatedly timed, including all manufacturers, during 1 business week at each clinic. Mean staff time for a remote transmission and an in-person visit were calculated, including all clinical and administrative (e.g: scheduling, documentation) activities related to the encounter. Annual staff time for follow-up of 1 patient was modeled using CIED transmission data for the 6 clinics, guidelines for CIED follow-up, and published literature. Results 124 clinic visits and 1,374 remote monitoring activities were observed. Staff time required per remote transmission ranged from 12.1–13.4 minutes (depending on the CIED type), and time per visit was 43.4–51.0 minutes. Including all remote and in-person follow-ups, the estimated total staff time per year to manage one pacemaker, ICD, CRT, and ICM patient was 2.3, 2.4, 2.4, and 9.3 hours, respectively (Table 1). Conclusion CIED clinic workflow is complex and requires significant staff time. Remote monitoring is an efficient complement to in-office visits, allowing for continuous follow-up of patients. Future research should examine heterogeneity in clinic processes to identify the most efficient workflow. Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Medtronic
- Subjects :
- business.industry
Remote patient monitoring
medicine.medical_treatment
Cardiac resynchronization therapy
Workload
medicine.disease
law.invention
Implantable defibrillators
Time and motion
Workflow
law
medicine
Artificial cardiac pacemaker
Cardiac monitors
Medical emergency
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 15229645 and 0195668X
- Volume :
- 41
- Database :
- OpenAIRE
- Journal :
- European Heart Journal
- Accession number :
- edsair.doi...........c0f6ffa30bb5aca4dac09de3826d6c9a