Back to Search
Start Over
Reducing Radiation Exposure During CRT Implant Procedures: Single-Center Experience With Low-Dose Fluoroscopy Settings and a Sensor-Based Navigation System (MediGuide)
- Source :
- Journal of Cardiovascular Electrophysiology. 27:1337-1343
- Publication Year :
- 2016
- Publisher :
- Wiley, 2016.
-
Abstract
- Sensor-Based Navigation and CRT ImplantationIntroduction Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. Methods A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). Results Overall, MDG was associated with an 82.1% reduction in IR exposure (393 μGray·m2 vs. 2191 μGray·m2, P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 μGray·m2 vs. 2608 μGray·m2, P < 0.001) and 81.8% reduction with MDG (108 μGray·m2 vs. 595 μGray·m2, P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 μGray·m2 vs. 2608 μGray·m2, P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). Conclusion Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.
- Subjects :
- Implant procedures
Sensor based navigation
medicine.diagnostic_test
business.industry
medicine.medical_treatment
Low dose
Cardiac resynchronization therapy
030204 cardiovascular system & hematology
Single Center
030218 nuclear medicine & medical imaging
Radiation exposure
03 medical and health sciences
0302 clinical medicine
Physiology (medical)
parasitic diseases
medicine
Fluoroscopy
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Electromagnetic tracking
Subjects
Details
- ISSN :
- 10453873
- Volume :
- 27
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiovascular Electrophysiology
- Accession number :
- edsair.doi...........bf643e05a6f6a634e50e5bb1cb9832cd