Multicenter Comparison of Truncated Biphasic Shocks and Standard Damped Sine Wave Monophasic Shocks for Transthoracic Ventricular Defibrillation

Authors :
Douglas L. Packer
Ramakota K. Reddy
Gust H. Bardy
Raymond Yee
Richard M. Luceri
Ralph Lazzara
Francis E. Marchlinski
Thomas Mattioni
Christopher L. Fellows
Blair D. Halperin
Richard A. Kronmal
David Wilber
Thomas S. Ahern
Seth J. Worley
Donald A. Chilson
Arjun D. Sharma
Source :
Circulation. 94:2507-2514
Publication Year :
1996
Publisher :
Ovid Technologies (Wolters Kluwer Health), 1996.

Abstract

Background The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience with truncated biphasic waveforms in implantable cardioverter-defibrillators, we compared the efficacy of a truncated biphasic waveform with that of a standard damped sine monophasic waveform for transthoracic defibrillation. Methods and Results The principal goal of this multicenter, prospective, randomized, blinded study was to compare the first-shock transthoracic defibrillation efficacy of a 130-J truncated biphasic waveform with that of a standard 200-J monophasic damped sine wave pulse using anterior thoracic pads in the course of implantable cardioverter-defibrillator testing. Pad-pad ECGs were also examined after transthoracic defibrillation. After the elimination of data for 24 patients who did not meet all protocol criteria, the results from 294 patients were analyzed. The 130-J truncated biphasic pulse and the 200-J damped sine wave monophasic pulse resulted in first-shock efficacy rates of 86% and 86%, respectively ( P =.97). ST-segment levels measured 10 seconds after the shock in 151 patients in sinus rhythm were −0.26±1.58 and −1.86±1.93 mm for the 130- and 200-J shocks, respectively ( P Conclusions We found that 130-J biphasic truncated transthoracic shocks defibrillate as well as the 200-J monophasic damped sine wave shocks that are traditionally used in standard transthoracic defibrillators and result in fewer ECG abnormalities after the shock.

Details

ISSN :
15244539 and 00097322
Volume :
94
Database :
OpenAIRE
Journal :
Circulation
Accession number :
edsair.doi...........b340a301d0eaec73e2809843d624e512
Full Text :
https://doi.org/10.1161/01.cir.94.10.2507