Back to Search
Start Over
Entrainment measurements in annular flow
- Publication Year :
- 1997
- Publisher :
- Office of Scientific and Technical Information (OSTI), 1997.
-
Abstract
- Air/water and vapor/freon were utilized to scale and simulate annular two-phase flow for high pressure steam/water conditions. A unique vapor/liquid Freon loop was built to obtain the high pressure data. The results were compared with two correlations available in the open literature. The Ishii and Mishima dimensionless group was able to scale the data remarkably well even for vapor/liquid Freon. However, the correlation needs to be adjusted for high Weber numbers of the gas phase.
Details
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........b265584ad9ae2135de5c64315061f72b
- Full Text :
- https://doi.org/10.2172/505284