Back to Search Start Over

Entrainment measurements in annular flow

Authors :
Stephen G. Beus
A. Assad
M. de Bertodano
C. Jan
Publication Year :
1997
Publisher :
Office of Scientific and Technical Information (OSTI), 1997.

Abstract

Air/water and vapor/freon were utilized to scale and simulate annular two-phase flow for high pressure steam/water conditions. A unique vapor/liquid Freon loop was built to obtain the high pressure data. The results were compared with two correlations available in the open literature. The Ishii and Mishima dimensionless group was able to scale the data remarkably well even for vapor/liquid Freon. However, the correlation needs to be adjusted for high Weber numbers of the gas phase.

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........b265584ad9ae2135de5c64315061f72b
Full Text :
https://doi.org/10.2172/505284