Back to Search Start Over

Measurements of the Dielectric Properties of Irradiated Low-Loss by Microwave Reflectometry and Micro-Calorimetry

Authors :
S.N. Buckley
P. Agnew
Source :
MRS Proceedings. 189
Publication Year :
1990
Publisher :
Springer Science and Business Media LLC, 1990.

Abstract

An rf reflectometer has been used to measure dielectric losses in alumina ceramics during irradiation by 3 MeV protons. The equipment was able to detect tan ȯ changes of 5×10−5, but calibration by micro-calorimetry revealed large systematic losses, up to 2.5×10−3 Irradiation at 300 K resulted in a progressive increase in dielectric loss but no prompt increments.