Flow measurement in MRI using arterial spin labeling with cumulative readout pulses-Theory and validation

Authors :
Edward V. R. DiBella
Yi Wang
Dennis L. Parker
Seong Eun Kim
Source :
Medical Physics. 37:5801-5810
Publication Year :
2010
Publisher :
Wiley, 2010.

Abstract

Purpose: This article systematically examines arterial spin labeling (ASL) as a flow quantification technique through theoretical simulation,in vitro, and in vivo experiment. The authors present a novel imaging pulse sequence design consisting of a single ASL magnetization preparation followed by Look-Locker-like image readouts. Bloch-equation-based modeling has been developed and validated using a hemodialyzer as a tissue-mimicking flow phantom. Methods: After the single in-plane slice-selective double inversion magnetization preparation, multiple TFL readouts are acquired with linear k-space ordering, causing a signal variation that depends on through-slice flow velocity. Computer simulations were performed to assess the behavior of the flow-dependent ASL signal as a function of varying imaging parameters. The signal was optimized by choosing imaging parameters that maximize the simulated flow-sensitive signal. Furthermore, a hemodialyzer which mimics blood flow in human tissues was tested with a wide range of flow rates. An exponential curve fitting of the flow-sensitive dynamics to the model derived from Bloch equations provides a method to estimate through-slice velocity for varying flow rates on the hemodialyzer andin vivo human brain. Results: The flow dependency of the ASL signal and the sensitivity of the ASL signal to imaging parameters were demonstrated. Experimental results from a hemodialyzer when fitted with a Bloch-equation-based model provide flow measurements that are consistent with ground truth velocities. Human brain velocity mapping was obtained as well. Conclusions: The results provide evidence that the proposed pulse sequence design is an effective technique to measure total fluid flow through image voxels. The unique combination of the two main features, multiple-image readout after a single ASL preparation and linear acquisition ordering in the phase encoding direction in TFL imaging, make this technique an appealing flowimaging method to quantify through-plane flow in a time-efficient manner.

Details

ISSN :
00942405
Volume :
37
Database :
OpenAIRE
Journal :
Medical Physics
Accession number :
edsair.doi...........b0a8dc72319b2821adb43b4f64042dca
Full Text :
https://doi.org/10.1118/1.3501881