CFD application in optimization improvement design of a low specific speed centrifugal pump impeller

Authors :
Xin-liang Feng
Jin-jin Guo
Qing-chun Zheng
Source :
2010 International Conference on Mechanic Automation and Control Engineering.
Publication Year :
2010
Publisher :
IEEE, 2010.

Abstract

There are some problems of hydraulic performance in the low specific speed centrifugal pump, such as small capacity, low efficiency. In this paper, the long-short blade method and enlarging flow method is applied to optimize the impeller. In design of impeller optimizing, author uses CFD technology to predict model performance, analyzes the test results, finally gets the best parameters combination of the impeller. Testing result for the prototype of product proves that the optimized impeller model has a good hydraulic performance, indicating that CFD will help designer optimize centrifugal pumps.

Details

Database :
OpenAIRE
Journal :
2010 International Conference on Mechanic Automation and Control Engineering
Accession number :
edsair.doi...........ae663da1ed9cb80c13ebac92916e4e0f
Full Text :
https://doi.org/10.1109/mace.2010.5535659