Back to Search
Start Over
‘Blue bubble’ technique: an ab interno approach for Descemet separation in deep anterior lamellar keratoplasty using trypan blue stained viscoelastic device
- Source :
- Clinical & Experimental Ophthalmology. 46:275-279
- Publication Year :
- 2017
- Publisher :
- Wiley, 2017.
-
Abstract
- BACKGROUND In this study, we examined a novel variant of 'big-bubble' deep anterior lamellar keratoplasty using trypan-blue-stained viscoelastic device for the creation of a pre-descemetic bubble. METHODS Ten corneoscleral rims were mounted on an artificial anterior chamber (AC). The AC was filled with air through a limbal paracentesis. A Melles' triangulated spatula was inserted through the paracentesis, with its tip penetrating the AC, was then slightly retracted and pushed into the deep stroma above the roof of the paracentesis. A mixture of trypan blue and viscoelastic device (Healon, Abbott Medical Optics, Abbott Park, Illinois) was injected into this intra-stromal pocket using a 27-G cannula to create a pre-descemetic separation bubble. Bubble type and visualization of dyed viscoelastic device were noted. The method was later employed in three cases. RESULTS In all 10 corneoscleral rims, the technique successfully created a visible pre-descemetic (type 1) bubble that could be expanded up to the predicted diameter of trephination. Subsequent trephination and the removal of corneal stroma were uneventful. In two out of four clinical cases, a type 1 bubble was created, while in two others, visco-dissection failed and dyed viscoelastic was seen in the AC. CONCLUSIONS The presented technique holds promise of being a relatively easy to perform, predictable and well-controlled alternative for achieving a type 1 bubble during deep anterior lamellar keratoplasty surgery. The trypan-blue-stained viscoelastic device facilitates proper visualization and control of the separation bubble and assists in identifying the penetrance to the separation bubble prior to removal of the stromal cap.
- Subjects :
- business.industry
medicine.medical_treatment
Bubble
Lamellar keratoplasty
Cannula
Viscoelasticity
03 medical and health sciences
Ophthalmology
chemistry.chemical_compound
0302 clinical medicine
medicine.anatomical_structure
chemistry
Cornea
030221 ophthalmology & optometry
medicine
Trypan blue
business
030217 neurology & neurosurgery
Corneal transplantation
Biomedical engineering
Subjects
Details
- ISSN :
- 14426404
- Volume :
- 46
- Database :
- OpenAIRE
- Journal :
- Clinical & Experimental Ophthalmology
- Accession number :
- edsair.doi...........aa15102b6c60cefbedcbf2bcde0fddc2