Abstract
- A design procedure, based on a one-dimensional simulation, is presented for an ejection refrigeration system. Heat exchangers are included in the calculation, accounting for temperature differences between the fluids and for pressure losses. The ideal gas assumption, which is quite common in the literature concerning ejector systems, is avoided. Furthermore, the supersonic diffuser is designed with a continuous profile, without cylindrical piece, controlling the variation of momentum along the flow path and accounting for friction. At design conditions, this should reduce the irreversibility due to the normal shock. A comparison between different operating fluids is presented and R245fa is selected. The results of the design procedure and the expected performance, in terms of first and second law efficiency, are presented.
- Subjects :
- Engineering
Renewable Energy, Sustainability and the Environment
business.industry
Energy Engineering and Power Technology
Mechanical engineering
Refrigeration
Injector
Ideal gas
law.invention
Shock (mechanics)
Diffuser (thermodynamics)
Fuel Technology
Nuclear Energy and Engineering
law
Heat exchanger
Exergy efficiency
Supersonic speed
business
Subjects
Details
- ISSN :
- 01968904
- Volume :
- 54
- Database :
- OpenAIRE
- Journal :
- Energy Conversion and Management
- Accession number :
- edsair.doi...........a877dc262af8c6211fae954e09ceb2d6
- Full Text :
- https://doi.org/10.1016/j.enconman.2011.09.015