Back to Search Start Over

Commissioning of the China-ADS Injector-I Testing Facility

Authors :
Yan, Fang
Cao, Jianshe
Chi, Yunlong
Ge, Rui
Geng, Huiping
Gu, Shengdong
Guo, Dizhou
Huang, Tong-Ming
Jing, Xiaping
Li, Heng
Liu, Rong
Long, Fengli
Meng, Cai
Ouyang, Huafu
Pan, Weimin
Peng, Quanling
Sui, Yanfeng
Wang, Jianli
Wang, Shengchang
Xue, Zhou
Ye, Qiang
Zhao, Yaliang
Publication Year :
2016
Publisher :
JACoW, Geneva, Switzerland, 2016.

Abstract

The 10 MeV accelerator-driven subcritical system (ADS) Injector I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The ion source was installed since April of 2014, periods of commissioning are regularly scheduled between installation phases of the rest of the injector. 6.05 MeV proton energy has been achieved with average beam current of 10 mA by 7 SC spoke cavities at present. This contribution reports the details of the commissioning results together with the challenges of the CW machine commissioning.<br />Proceedings of the 7th Int. Particle Accelerator Conf., IPAC2016, Busan, Korea

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.doi...........a182edc69c2c885edaa1aff5e9d17f48
Full Text :
https://doi.org/10.18429/jacow-ipac2016-weoba02