Back to Search
Start Over
Numerical electromagnetic analysis of lightning protection system over lossy ground
- Source :
- 2008 Asia-Pacific Symposium on Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility.
- Publication Year :
- 2008
- Publisher :
- IEEE, 2008.
-
Abstract
- The electromagnetic transients of lightning protection system (LPS) under direct lightning strike is studied using NEC2. By employing antenna return-stroke model, lightning channelpsilas inducing effect and finite conductivity of ground are all taken into account. Results show that the lightning channelpsilas inducing effect tends to decrease the current flowing through horizontal conductors, and increases the current flowing through vertical conductors near the striking point. The results obtained under perfect ground assumption have a good agreement with the published experimental results. The simulation also predicts that the finite conductivity of the ground affects the branch current significantly, it increase the LPSpsilas current dissipating efficiency, the higher the soil resistivity, the more uniform the current flowing in vertical conductors.
Details
- Database :
- OpenAIRE
- Journal :
- 2008 Asia-Pacific Symposium on Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility
- Accession number :
- edsair.doi...........a12000fc87ef76096103291342628861