Back to Search Start Over

BOTDA-based DTS robustness demonstration for subsea structure monitoring applications

Authors :
Etienne Rochat
Fabien Ravet
Marc Nikles
Source :
SPIE Proceedings.
Publication Year :
2015
Publisher :
SPIE, 2015.

Abstract

We demonstrate that BOTDA is the equipment of choice for Distributed Temperature Sensing (DTS) when challenging components such as Wet Mate Connectors (WMC) and Fiber Optic Rotary Joints (FORJ) are inserted in the sensing line. The parameter of Temperature Measurement Dead Zone (TMDZ) is introduced to support the discussion and quantify possible impairments. A laboratory qualification test with real FORJ and WMC is conducted confirming the theoretical expectations. The system is then implemented offshore demonstrating that FORJ and WMC do not affect the sensing operation in field environment.

Details

ISSN :
0277786X
Database :
OpenAIRE
Journal :
SPIE Proceedings
Accession number :
edsair.doi...........a09d611d81d9d25ff33c11948d2db846
Full Text :
https://doi.org/10.1117/12.2194154