Back to Search Start Over

SARS-CoV-2 Antibody Lateral Flow Assay for antibody prevalence studies following vaccine roll out: a Diagnostic Accuracy Study

Authors :
Steven Riley
Graham S Cooke
Paul Elliott
Paul Randell
Maria Prendecki
Candice Clarke
Alexandra H C Cann
Maya Moshe
Michelle Willicombe
Wendy S. Barclay
Peter Kelleher
Jonathan Brown
Helen Ward
Tina Thomson
Deborah Ashby
Ara Darzi
Anjna Badhan
Publication Year :
2021
Publisher :
Cold Spring Harbor Laboratory, 2021.

Abstract

BackgroundLateral flow immunoassays (LFIAs) have the potential to deliver affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of SARS-CoV-2 vaccine.MethodsThis is a prospective diagnostic accuracy study.SettingSampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Laboratory analyses were performed across Imperial College London sites and university facilities.ParticipantsTwo cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following SARS-CoV-2 vaccine booster, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination, and 21 day follow up. A total of 186 paired samples were collected.InterventionsDuring the participants visit, capillary blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG were detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA.Main outcome measuresThe accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay.ResultsUsing the threshold value for positivity on serological testing of ≥7.10 BAU/ml, the overall performance of the test produces an estimate of sensitivity of 91.94% (95% CI 85.67% to 96.06%) and specificity of 93.55% (95% CI 84.30% to 98.21%) using the Abbott assay as reference standard.ConclusionsFortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveys, but does not meet criteria for individual testing.

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........9fdcd2ce28870ad5f15d63d080c600c6