Back to Search
Start Over
Fatigue monitoring of coated steel belts by means of magnetic inspection
- Source :
- Insight - Non-Destructive Testing and Condition Monitoring. 65:153-160
- Publication Year :
- 2023
- Publisher :
- British Institute of Non-Destructive Testing (BINDT), 2023.
-
Abstract
- Coated steel belts (CSBs) are the primary load-bearing components of elevators. As a result, they may experience severe fatigue failure during their long-term service. In this study, a flexible fatigue fixture for CSBs is designed to simulate the CSB fatigue damage process for implementing a tensile fatigue test. The magnetic induction intensity signal on the surface of the CSB in a geomagnetic field environment is recorded using a high-precision weak magnetic sensor. Moreover, the CSB fatigue damage process is monitored online via the acquired magnetic induction intensity value. The fatigue test results indicate the following: the variation in the magnetic induction intensity signal curve can reflect the entire fatigue failure process when the CSB is under stress; the fatigue failure process of the steel wire inside the CSB does not occur smoothly as its progress occurs in stages; and the variation trend in the residual value between the magnetic induction intensity and fitting curves effectively indicates the degree of fatigue damage caused to the CSB.
- Subjects :
- Mechanics of Materials
Mechanical Engineering
Materials Chemistry
Metals and Alloys
Subjects
Details
- ISSN :
- 13542575
- Volume :
- 65
- Database :
- OpenAIRE
- Journal :
- Insight - Non-Destructive Testing and Condition Monitoring
- Accession number :
- edsair.doi...........9cabe9e6a4178a5ab6cd97dd3c2dba14