Back to Search Start Over

Effects of water exchange on the measurement of myocardial perfusion using paramagnetic contrast agents

Authors :
Karen May-Newman
Robert M. Judd
Scott B. Reeder
Source :
Magnetic Resonance in Medicine. 41:334-342
Publication Year :
1999
Publisher :
Wiley, 1999.

Abstract

To investigate the effects of water exchange on quantification of perfusion, data were acquired in isolated hearts (n = 11) and used to develop a model of exchange. Myocardial T 1 was measured 3 times/sec during step changes in concentration of intravascular (polylysine-gadolinium-diethylene-triamine-pentaacetic acid) and extracellular (gadoteridol) agents. For the intravascular agent, the change in 1/T 1 (ΔR 1 ) was lower than predicted by fast exchange (2.7 ± 0.5 vs. 7.8 sec -1 , respectively), and suggested an intra-extravascular exchange rate of 3 Hz. For the extracellular agent, contrast kinetics were similar to those of similarly sized molecules (wash-in time constant 38 ± 5 sec), and the data suggested fast interstitial-cellular exchange. Modeling showed that perfusion is underestimated for both agents if exchange is ignored, although the relationships of measured to actual perfusion were monotonic. We conclude that myocardial water exchange strongly affects first-pass enhancement but that ignoring the effects of exchange may still provide reasonable estimates of regional perfusion differences.

Details

ISSN :
15222594 and 07403194
Volume :
41
Database :
OpenAIRE
Journal :
Magnetic Resonance in Medicine
Accession number :
edsair.doi...........97e5f1281c0ab117633c00e045439272
Full Text :
https://doi.org/10.1002/(sici)1522-2594(199902)41:2<334::aid-mrm18>3.0.co;2-y