Ultraminiaturized Milliwatt-Scale Permanent Magnet Generators
- Source :
- TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.
- Publication Year :
- 2007
- Publisher :
- IEEE, 2007.
-
Abstract
- This paper reports the design, fabrication and experimental characterization of ultraminiaturized, axial-flux, permanent-magnet (PM) generators intended for milliwatt range systems. The miniaturization of PM machines is attractive because scaling laws are favorable, but integration of ultra-small permanent magnets is challenging. The generators are 2-pole, multi-turn, 2-mm diameter machines. A single-phase, open-circuit voltage of 51 mVrms has been measured at 392 krpm, which approximately corresponds to 3.6 mW of DC power to a load resistance at the point of maximum power transfer, indicating that this approach shows great promises for milliwatt-scale power devices.
Details
- Database :
- OpenAIRE
- Journal :
- TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference
- Accession number :
- edsair.doi...........9063844782f65ae3161eb7266ad8f846
- Full Text :
- https://doi.org/10.1109/sensor.2007.4300276