Back to Search Start Over

Fracture Parameters of Concrete from Drill-Core Specimens from Objects at the Transgas Gas Control Center

Authors :
Petr Frantík
Pavla Rovnaníková
Tomáš Majda
Zbyněk Keršner
Petr Daněk
Hana Šimonová
Source :
Solid State Phenomena. 292:85-90
Publication Year :
2019
Publisher :
Trans Tech Publications, Ltd., 2019.

Abstract

This paper presents the results of fracture tests conducted on nine concrete specimens from drill-cores taken from three selected objects located at the former Transgas Gas Control Center in Prague. The specimens were provided with a chevron notch before being tested in three-point bending. The evaluation included arithmetic mean values and basic statistics for the static modulus of elasticity, fracture toughness and specific fracture energy of the assessed concrete specimens.

Details

ISSN :
16629779
Volume :
292
Database :
OpenAIRE
Journal :
Solid State Phenomena
Accession number :