Demonstration of multiple contrast agent imaging for the next generation color X-ray CT
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 958:162801
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- X-ray computed tomography (CT) is widely used for non-invasive diagnostic imaging of the inside of the human body. It should be noted that the approximate effective radiation dose in a patient is 10 mSv. Under such an environment, X-ray photons are severely piled-up. Therefore, conventional CT only reconstructs energy integrated image, which may consist of beam hardening artifacts that have proven to be a problem. In contrast, photon counting CT (PC-CT) offers a low-dose multicolor CT imaging. The PC-CT also enables K-edge imaging that can improve the blood–tissue contrast using specific contrast agents. Moreover, the PC-CT has great advantages in (1) the simultaneous imaging of multiple contrast agents, and (2) the absolute quantification of contrast agents. Owing to these advantages, the PC-CT system can provide more detailed tissue diagnosis than conventional CT systems. Recently, we proposed a novel PC-CT system (Morita et al., 2017; Arimoto et al., 2017, Maruhashi et al., 2018) consisting of multipixel photon counter (MPPC) coupled with a high-speed scintillator, which is a cost-effective and easy to assemble system, as compared to other PC-CT devices based on cadmium zinc telluride. In this paper, we operated the K-edge imaging of specific contrast agents using a 16-channel MPPC PC-CT system. Our PC-CT system established appropriate energy thresholds and operated the simultaneous imaging of multiple contrast agents such as iodine and gadolinium. In addition, we estimated the absolute concentration of these contrast agents. The results show that our PC-CT system can provide more accurate diagnostic medical imaging, as compared to the conventional CT system.
- Subjects :
- Physics
Nuclear and High Energy Physics
Photon
010308 nuclear & particles physics
Gadolinium
media_common.quotation_subject
X-ray
chemistry.chemical_element
Scintillator
01 natural sciences
Photon counting
030218 nuclear medicine & medical imaging
Cadmium zinc telluride
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
chemistry
0103 physical sciences
Medical imaging
Contrast (vision)
Instrumentation
media_common
Biomedical engineering
Subjects
Details
- ISSN :
- 01689002
- Volume :
- 958
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi...........8d38b9d26b63bc5406274426c49b5378