Back to Search Start Over

Cross section measurement of neutron capture reaction based on back-streaming white neutron source at China spallation neutron source

Authors :
Wang Li-Jiao
Zhang Yu-liang
Feng Chang-Qing
Sun Qi
Zhao Yubin
Sun Xiao-Yang
Fan Rui-Rui
Sun Hong
Han Changcai
Wu Qing-Biao
Yu Yong-Ji
Kang Ling
Tang Jing-Yu
Zhu Xinghua
Jiang Zhi-Jie
Chen Zhen
Tan Zhi-Xin
An Qi
Luan Guang-Yuan
Gao Ke-Qing
Song Zhaohui
Bai Huaiyong
Tang Xin-Yi
Jiang Haoyu
Wen Jie
Wang Pengcheng
Zhu Dan-Yang
Ning Chang-Jun
Qi Bin-Bin
Chen Qiping
Chen Hao-Lei
Chen Yong-Hao
Han Zijie
Li Qiang
Li Jia-Wen
Huang Xi-Ru
Zhou Zu-Ying
He Yong-Cheng
Li Xiao
Wang Zhao-Hui
Wang Taofeng
Zhang Qi-Wei
Ji Xu-Yang
Zhang Xian-Peng
Gu Min-Hao
Jing Han-Tao
Cui Zeng-Qi
Wu Xiaoguang
Song Ying-Peng
Mu Qi-Li
Ren Zhi-Zhou
Tang Hong-Qing
Ji Xiao-Lu
Li Chao
Zhang Guohui
Wang Qi
Liu Xing-Yan
Yu Li
Yi Han
Bao Yu
He Guo-Zhu
Li Lun
Zhang Lin-Hao
Liu Shubin
Zhang Zhi-Yong
Bao Jie
Yang Yi-Wei
Kang Ming-Tao
Ruan Xi-Chao
Sun Kang
Sun Zhijia
Yu Tao
Cao Ping
Zhu Ke-Jun
Li Bo
Ren Jie
Zhu Peng
Huang Han-Xiong
Wu Xuan
Zhou Lu-Ping
Xie Li-Kun
Huang Wei-Ling
Hong Yang
Liu Rong
Wen Zhongwei
Chen Yu-Kai
Tian Bin-Bin
Jiang Wei
Li Yang
Source :
Acta Physica Sinica. 70:222801
Publication Year :
2021
Publisher :
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, 2021.

Abstract

The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV–10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF2 detector units. The BaF2 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 197Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.

Details

ISSN :
10003290
Volume :
70
Database :
OpenAIRE
Journal :
Acta Physica Sinica
Accession number :
edsair.doi...........8c4c6414dd3f0af81e36d5266f776210