Analysis and Research on Dynamic Characteristics of Bulb Tubular Pumping Station Structure
- Source :
- Advanced Materials Research. :1917-1921
- Publication Year :
- 2012
- Publisher :
- Trans Tech Publications, Ltd., 2012.
-
Abstract
- This paper was combined with the third Huaian pumping station to study the dynamic characteristics of the bulb tubular pumping station. By using dynamic finite element analysis method to create Huaian pumping station modes. Then using ANSYS Model Analysis and harmonic response analysis, the vibration modes and dynamic response were researched deeply. According to the mode analysis results, the fundamental frequencies of upper pump house were determined for 1.36Hz and the fundamental frequencies of substructure were determined for 20.11Hz. The dynamic response of the bulb tubular pumping station structure under fluctuating pressures is calculated by ANSYS harmonic response analysis, and the results show that dynamic displacement satisfied the maximum allowable of architectural construction permission,so it can satisfy design requirement, which provides references value for other tubular pumping station in anti-vibration design.
Details
- ISSN :
- 16628985
- Database :
- OpenAIRE
- Journal :
- Advanced Materials Research
- Accession number :