Evaluation of electromagnetic loads on various design options of the ITER diagnostic upper port plug during plasma disruptions

Authors :
Duck Young Ku
S. Pak
Duck-Hoi Kim
Chang Rae Seon
Spencer Pitcher
Dong-Keun Oh
MunSeong Cheon
H.G. Lee
Hogun Jhang
Source :
Fusion Engineering and Design. 86:1877-1881
Publication Year :
2011
Publisher :
Elsevier BV, 2011.

Abstract

Electromagnetic (EM) loads due to eddy current and halo current during plasma disruptions are evaluated for the ITER diagnostic upper port plug. To reduce strong EM loads acting on the port plug fixed to the vacuum vessel like a cantilever beam, three design options have been considered: removal of the diagnostic first wall, slitting of the diagnostic shield module and recess of the port plug. The main focus of the present study is to examine the efficacy of these options in terms of EM loads on the upper port plug. It is found that making slits is more effective than removing the first wall. It is also shown that the upper port plug needs to be recessed to reduce the EM load induced by halo current.