Back to Search
Start Over
Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
- Source :
- Reports of Practical Oncology & Radiotherapy. 25:139-145
- Publication Year :
- 2020
- Publisher :
- VM Media SP. zo.o VM Group SK, 2020.
-
Abstract
- Purpose The purpose of the present study was to perform an independent calculation of dosimetric parameters associated with a new 192Ir brachytherapy source model, IRAsource. Materials and methods The parameters of air kerma strength (AKS), dose rate constant (DRC), geometry function (GF), radial dose function (RDF), as well as two-dimensional (2D) anisotropy function (AF) of IRAsource 192Ir source model were calculated in this study. The MC n-particle extended (MCNPX) code was also employed for simulating high dose rate (HDR), IRAsource and 192Ir source; and formalism was used for calculating dosimetry parameters based on task group number 43 updated report (TG-43 U1). Results The results of this study were consistent with the ones reported about the IRAsource source by Sarabiasl et al. The AKS per 1 mCi activity and the DRC values were also equal to 3.65 cGycm2 h–1 mCi–1 and 1.094 cGyh–1U–1; respectively. The comparison of the results of the DRC and the RDF reported by Sarabiasl et al. also validated the 192Ir IRAsource simulation in this study. Moreover, the AFs of IRAsource source model were in a good agreement with those of Sarabiasl et al. at different distances, which could be attributed to identical geometries. Conclusion In line with those reported by Sarabiasl et al., the results of this study confirmed the IRAsource 192Ir source for clinical uses. The calculated dosimetric parameters of the IRAsource source could be utilized in clinical practices as input data sets or for validation of treatment planning system calculations.
- Subjects :
- Physics
medicine.medical_treatment
Monte Carlo method
Brachytherapy
Brachytherapy source
030218 nuclear medicine & medical imaging
Computational physics
03 medical and health sciences
Kerma
0302 clinical medicine
Oncology
030220 oncology & carcinogenesis
medicine
Dosimetry
Radiology, Nuclear Medicine and imaging
Dose rate
Anisotropy
Radiation treatment planning
Subjects
Details
- ISSN :
- 15071367
- Volume :
- 25
- Database :
- OpenAIRE
- Journal :
- Reports of Practical Oncology & Radiotherapy
- Accession number :
- edsair.doi...........820f43770948498f48316d751a078221
- Full Text :
- https://doi.org/10.1016/j.rpor.2019.12.022