Back to Search Start Over

GMTIFS: cryogenic rotary mechanisms for the GMT Integral-Field Spectrograph

Authors :
Gabe Bloxham
Colin Vest
Robert Boz
Brady Espeland
Rob Sharp
Dave Bundy
Bartholomew Fordham
Annino Vaccarella
John Davies
Nick Herald
John Hart
Source :
SPIE Proceedings.
Publication Year :
2016
Publisher :
SPIE, 2016.

Abstract

A representative range of the rotary mechanisms proposed for use in GMTIFS is described. All are driven by cryogenically rated stepper motors. For each mechanism, angular position is measured by means of eddy current sensors arranged to function as a resolver. These measure the linear displacement of a decentered aluminum alloy target in two orthogonal directions, from which angular position is determined as a function of the displacement ratio. Resolver function and performance is described. For each mechanism, the mechanical design is described and the adequacy of positioning repeatability assessed. Options for improvement are discussed.

Details

ISSN :
0277786X
Database :
OpenAIRE
Journal :
SPIE Proceedings
Accession number :