Back to Search Start Over

Neutron Capture Measurements at the ṉTOF Facility

Authors :
W.I. Furman
C. A. Papachristodoulou
F. Alvarez-Velarde
S. Andriamonje
G. Vannini
S. Walter
Ralf Plag
Carlos Guerrero
Gerald Badurek
U. Abbondanno
Heinz Oberhummer
S. David
C. Stephan
F. Gunsing
P. F. Mastinu
G. Tagliente
Cristian Massimi
S. Lukic
D. Cano-Ott
F. Gramegna
R. Vlastou
E. Berthoumieux
J. Andrzejewski
C. Paradela
H. Leeb
Isabel Lopes
N. Colonna
V. Chepel
L. Audouin
I. Savvidis
K. Wisshak
F. Voss
E. Kossionides
G. Rudolf
J. Salgado
G. Cortes
C. Carrapiço
Javier Praena
Michael Wiescher
C. Santos
A. Poch
J. Marganiec
A. Plukis
M. C. Vincente
L. Tavora
G. Aerts
Vasilis Vlachoudis
P. Baumann
P. E. Koehler
F. Bečvář
L. Ferrant
Roberto Capote
M. Krtička
F. Calviño
P.A. Assimakopoulos
F. Neves
P. M. Milazzo
R. Ferreira-Marques
T. Martinez
A. Lindote
L. Sarchiapone
M. Embid-Segura
L. Perrot
A. Herrera-Martinez
D. Karamanis
F. Käppeler
N. Patronis
James L. Cox
Arnaud Ferrari
Manuel Lozano
Matthias Heil
J. Pancin
D. Villamarin
I. Duran
E. Jericha
P. Cennini
Y. Kadi
M. Mosconi
I. Dillman
S. O'Brien
Marco Calviani
R. Terlizzi
P. Pavlopoulos
W. Dridi
A. Ventura
Rene Reifarth
J. M. Quesada
L. Tassan-Got
M. Dahlfors
P. Vaz
Aaron Couture
A. Pavlik
C. Domingo-Pardo
H. Álvarez
C. Lamboudis
J. L. Tain
C. Rubbia
Isabel S. Gonçalves
S. Marrone
M. Kerveno
K. Fujii
A. Mengoni
C. Pretel
C. Eleftheriadis
D. Karadimos
E. González-Romero
Source :
AIP Conference Proceedings.
Publication Year :
2009
Publisher :
AIP, 2009.

Abstract

Nuclear astrophysics, advanced nuclear technology and nuclear structure physics present many cases that require neutron capture reaction data with high precision. In particular, refined data are needed for stellar nucleosynthesis, for nuclear waste transmutation studies, and for the design of generation IV reactors. The measurements take profit of the pulsed neutron beam of the n_TOF facility at CERN, which is generated by proton‐induced spallation reactions on a massive lead target. The low repetition rate of the proton beam, the high instantaneous neutron flux, and the favourable background conditions in the experimental area make this facility unique for high resolution time‐of‐flight measurements of neutron induced reaction cross sections. The n_TOF collaboration is presently operating two different experimental set‐ups. The first consists of two low‐neutron sensitivity C6D6 detectors with the analysis relying on the Pulse Height Weighting technique. In addition, a Total Absorption Calorimeter, consis...

Details

Database :
OpenAIRE
Journal :
AIP Conference Proceedings
Accession number :
edsair.doi...........81fb1db7037173240dd921c53a2d2c57