Back to Search Start Over

A Design Study for a New Neutron Counter Based on an Annular Tube-Type 3He Detector through a Monte Carlo Simulation

Authors :
C. Y. Lee
Hee-Sung Shin
Ho-Dong Kim
K. J. Park
J. H. Jung
T. H. Lee
J. S. Joo
Source :
Nuclear Technology. 168:50-54
Publication Year :
2009
Publisher :
Informa UK Limited, 2009.

Abstract

A new well-type neutron counter that is composed of a double-layered annular tube 3 He detector, a polyethylene moderator, and a lead gamma shield has been conceptually designed through an MCNPX simulation. A computer program that generates MCNPX input simulating neutron counterperformance has been developed with 28 parameters to describe the geometrical structure of the neutron counter and source position. The neutron counter has been optimized to have 72.0-cm diameter X 68.3-cm height with a double-layered annular tube 3 He detector of 50-cm length and 2.5-cm thickness through repeated MCNPX simulation with the computer program. The neutron counting efficiency appeared to be >42.4%, and the spatial variance in the sample cavity of the counter was estimated to be

Details

ISSN :
19437471 and 00295450
Volume :
168
Database :
OpenAIRE
Journal :
Nuclear Technology
Accession number :
edsair.doi...........811513aca4df2676442d7d17f2d9bf19
Full Text :
https://doi.org/10.13182/nt09-a9100